      Effect of OT-Bridge System Versus Multiunit Abutment on the Passive Fit and Stresses Induced by CAD/CAM Fabricated All-on-Four Screw-Retained Prostheses (In Vitro Study)

      Abdelrahman Hazem, Shaimaa Lotfy Mohamed, Sara Ibrahim Soliman Mohamed

      Published: 2024-07-23 DOI: 10.17504/protocols.io.14egn6e4zl5d/v1
      AI 解读
      浏览 1381

      Abstract

      The hazardous effect of stresses

      induced by lack of passivity in screw-retained prostheses necessitates the

      selection of a suitable intermediate component between the implant fixture and

      the prosthetic framework. Thus, this study aims to evaluate passivity and

      stresses induced by CAD/CAM screw-retained prostheses fabricated using the OT

      Bridge system compared to the multi-unit abutment anchoring system. Two

      All-on-4 digital implant models will be fabricated, one for each group. Group 1;

      nine CAD/CAM frameworks will be fabricated employing the OT Bridge system

      abutments, while Group 2; nine CAD/CAM frameworks will be fabricated employing

      the multi-unit abutments. The passive fit will be assessed through microscopic

      measurement of misfit gaps at one terminal abutment, and micro-strain analysis

      will be conducted using strain gauges after functional load simulation.

      Steps

      Abstract

      1.

      The hazardous effect of stresses

      induced by lack of passivity in screw-retained prostheses necessitates the

      selection of a suitable intermediate component between the implant fixture and

      the prosthetic framework. Thus, this study aims to evaluate passivity and

      stresses induced by CAD/CAM screw-retained prostheses fabricated using the OT

      Bridge system compared to the multi-unit abutment anchoring system. Two

      All-on-4 digital implant models will be fabricated, one for each group. Group 1;

      nine CAD/CAM frameworks will be fabricated employing the OT Bridge system

      abutments, while Group 2; nine CAD/CAM frameworks will be fabricated employing

      the multi-unit abutments. The passive fit will be assessed through microscopic

      measurement of misfit gaps at one terminal abutment, and micro-strain analysis

      will be conducted using strain gauges after functional load simulation.

      2.

      Introduction

      The “All-on-4®” treatmentconcept played a great role in solvingmany 

      problems associated with the placement of implants in

      anatomically unsuitable ridges. The concept developed by

      Paulo-Malo is based on using straight and angled multi-unit abutments (MUA) to provide patientswith an immediatelyloaded full-arch restoration with only four implants. This method advocates tilting distal implants

      to enable; longer implant placement, improved prosthetic

      support, shorter cantilever arms, increased

      inter-implant distance, and improved anchorage in (1,2)(1,2) The idea of the OT Bridge fixed prosthetic system (Rhein83,

      Bologna, Italy) was born from the need to overcomethe disadvantages of angled multi-unit abutments and to greatly simplifyprosthetic proc(3)res.(3) This systemis based on the use of the low-profile OT Equator that is foremostused to provide retention for implant-retained overdentures. The morphology of this abutment allows a betterdistribution of the load to the surrounding tissues and it has greater fracture resistance compared to

      multiunit abu(4)nts. (4)

      The innovation of the OT Bridge systemlies in the use of an “extragrade” titanium abutment and a

      seeger system that guarantees the connection stability between the abutmentand OT Equator and passivation

      in the presence of serious disparallelism, the unique design of the “extragrade” abutment can overcome high implant divergence even in extreme casesover 80 degrees. The tolerance between the

      “extragrade” abutment and the OT Equator

      has been designed to compensate for minor misalignments that can be produced duringthe impression and the pouring of the cast mod(5) (5)  Another important aspect is relatedto seeger's retentive force. The tightness of the “extragrade” abutmenton the equator is not linked so much to the presenceof the connecting

      screw but to the mechanical retention given by the Seeger. The clinician will

      be able to use the abutmentsin "blind mode" without any connection screw, entrusting theconnection only to the seeger. Thus, it is possible

      to realize a fixed full-arch prosthesis by avoiding

      unaesthetic holes for the connection (6)ews. (6)  

      Passive fit of implant

      frameworks is crucial for achieving long-term success of osseointegration and

      preventing future complications(7-9)9) To assess framework

      fit, there are two in vitro approaches: modeling and dimensional measurement

      techniques. The modeling techniques (photoelastic analysis, strain gauge

      analysis &finite element analysis) are useful to assess the effect of the

      inaccuracy of fit of the prosthesis on the implant-bone complex. The

      dimensional measurements (stereomicroscopes, optical microscopes &

      micro-CT) are done mainly to measure the gap between the prosthesis and the

      implant as an indicator for framework(10)fit. (10) Strain gauge analysis is a technique for measuring

      micro-strains. It is based on the principle that certain materials change their

      electrical resistivity when subjected t(11)force. (11) They are efficient in quantifying

      strain, which could give a direct indication of the stress exerted within the (12)uctures. (12) Microscopes

      of differing magnifying powers can be used in vitro to directly measure th(10)sfit gap. (10)Microscopy has been used to evaluate the fit of partial or complete arch

      implant-supported fixed prostheses connected to external connection implants or

      mult(13-15,16,17,18 (13-15,16,17,18)

      The fixed OT Bridge

      prosthesis is reported to have numerous advantages versus multiunit abutments,

      however, to the best of our knowledge, no studies of comparison for

      misfit-induced stresses between MUA and OT-Bridge are today present in

      literature. Thus, the

      present study will be conducted in an attempt to investigate one of the

      advertised benefits of the new OT bridge system by assessing and comparing the

      passive fit of screw-retained CAD/CAM frameworks fabricated employing the

      modern OT Bridge system versus the traditional use of MUA as intermediate

      abutments in all-on-4 full arch rehabilitations.

      3.

      Sample Grouping:

      This study will comprise two equal groups based on

      the type of intermediate abutments employed for the fabrication of the

      screw-retained all-on-four implant frameworks, as follows:

      Group I: nine CAD/CAM frameworks will be fabricated

      on the first model utilizing the new OT Bridge system.

      Group II: nine CAD/CAM frameworks will be fabricated

      on the second model utilizing the multiunit abutment system.

      4.

      Laboratory Steps:

      A. CAD/CAM fabrication of Digital Implant Models (DIMs):

      Two digital implant

      models with soft tissue crests will be fabricated for installation of four digital

      implant analogs; two straight equidistant analogs anteriorly and two 30-degree

      angled analogs posteriorly. During designing, the model creator software will

      be used to create the slots for the strain gauges buccal and lingual to each

      implant and parallel to their long axes. The CAM files will be sent to a

      three-dimensional printer. Two models will be printed, one for each group. The

      digital implant analogs will be inserted into the models after their manufacturing.

      Four OT equator abutments will be installed to the first model, and four

      multiunit

      abutments will be installed to the second model.

      B. Capturing geometry:

                  For each model, the corresponding

      scan abutments will be installed. Using the laser scanning technique each model

      will be projected & scanned with an intraoral scanner.

      C. Digital designing of frameworks:

      For each model, the

      design of the corresponding frameworks will be virtually accomplished based on

      the computed position of the implants and using the virtual abutments in the

      digital library available for each of the two systems (Extragrade abutments and

      MUA retentive abutments), creating STL files for CAM production.

      D. CAM production of implant frameworks: :

      Eighteen Chrome-cobalt

      frameworks for a hybrid prosthesis design will be fabricated using a 5–axis

      milling machine to allow milling of the connection features and the screw

      channels.

      5.

      Methods of Evaluation:

      A. Frameworks passive fit:

      The passivity of fit will

      be evaluated by direct measurement of the vertical gap at one terminus of each framework

      under the stereomicroscope; one side of the framework will be screwed to its

      respective abutment in the working model using a screwdriver and torque wrench

      under torque specified by manufacturer, then retightened after 10 minutes to

      avoid preload screw loosening and discrepancies will be observed at the other

      unscrewed side. For each specimen, two stereomicrographs at the buccal and

      distal surfaces of the unscrewed side will be captured by a digital camera. Images

      will be then transferred to the computer software system for analysis and measurement

      of the gaps between the margins of the framework and corresponding a(19)nts. (19)

      B. Micro-strains induced around the implants:  

      For micro-strain

      analysis, strain gauges will be positioned & bonded in their places in each

      model. After functional simulation and load application the micro-strains

      induced around each implant will be assess(20)20)

      6.

      Data analysis:

      The data will first be

      recorded manually and then transferred into digital form. The obtained data will be recorded,

      tabulated, and statistically analyzed using the appropriate statistical tests.